PVC Line Fire Hose
fire-hose-double-jacket

  • Brass Fire Hose Nozzle
    1.5 Inch Brass Fire Hydrant Hose Nozzle
    1.5 Inch Brass Fire Hydrant Hose Nozzle 1.Product Introduction  This is a nozzle suit to connect with fire hydrant hose / rack hose. It is a device used to supply water, provided with a adaptor for connection to spray a dense, full stream of water. 2.Product Parameter  Material brass Size 1.5 inch Max working pressure 100 psi Discharge pattern Capable of complete shutoff, straight stream or any degree of conical fog 3. Product Feature Made of brass with rubber gaskets. Its robustness and ergonomic design makes it highly manoeuvrable by extreme impact resistance. The passage from closed to full jet or vaporized and is regulated by the rotation of the neck at the front.
    read more
  • Fire Fighting Hose Nozzle
    Spray Jet Brass Fire Fighting Hose Nozzle
    Spray Jet Brass Fire Fighting Hose Nozzle 1.Product Introduction  This is a nozzle suit to connect with fire hydrant hose / rack hose. It is a device used to supply water, provided with a adaptor for connection to spray a dense, full stream of water. 2.Product Parameter  Material Brass Size   1.5 inch Max working pressure 100 psi Flow rate 80 GPM Discharge pattern Capable of complete shutoff, straight stream or any degree of conical fog 3. Product Feature Made of solid brass. Its robustness and ergonomic design makes it highly manoeuvrable by extreme impact resistance. The passage from closed to full jet or vaporized and is regulated by the rotation of the neck at the front.
    read more
  • Water Curtain Nozzle
    Hydroshield Jumbo Fire Water Curtain Nozzle
    Hydroshield Jumbo Fire Water Curtain Nozzle   1.Product Description Winner Water Curtain nozzle is made of aluminum plate into a fan shape. It is suitable for petrochemical toxic gases and fire-fighting fires. Water curtain barriers are arranged to control the spread of smoke, reduce the temperature of fireworks, cover fires and save people.   2.Product Parameter     Model  WF-CN65 Max.Working Pressure 7 Bar Inlet Size 2.5" Flow Rate 1300 LPM -1600LPM Coupling BSP /Storz /NH /GOST /INST /Machino Material  Aluminium Alloy 3.Products Features  1) suitable for petrochemical toxic gases and fire-fighting fire; 2) comfortable with Quick Attach fire hose; 3) Water curtain barriers are arranged to control the spread of smoke, reduce the temperature of fireworks, cover fires and save people
    read more
  • Pump Suction Strainer
  • Suction Strainer
  • Defense Fire Nozzle
    580 LPM Fire Protection and Rescue Stream Spray Defense Fire Nozzle
    580 LPM Fire Protection and Rescue Stream Spray Defense Fire Nozzle Multi-Purpose Nozzles are technologically advanced nozzles with both solid bore and fog stream capability. The nozzle offers the flexibility to flow both at the same time or independently. Solid bore provides excellent reach and penetration at low pressure,whilst fog stream offers protection and rapid cooling. Inlet size is available in either 1-1/2" (38 mm),2" (50mm) or 2-1/2" (65 mm).   The Multi-Purpose Nozzles allows with both Straight stream and fog stream capability, Offering the Flexibility to flow both at the samt time or independenty. The fog mode can help the fire fighter release the heat at the same time of straight stream pattern.  Main Features 1. Strong Light Weight Aluminum Construction.  2. Tight Stream and 130° Wide Dense Fog Pattern.  3. Working Pressure: 100PSi or 7Bar.  4. Connection Size Available: 1.5'', 2.5''. 5. Connection Type Available: Storz, NH, BIC, or JIC. 6. Max Flow Distance: 34M.  Product Parameter  Type# Orifice Pressure (Bar) Flow Rate for Straight Stream (LPM) Flow Rate for Fog Pattern (LPM Flow Rate Total (LPM) QZH6.0/10ZB 3/8'' (10mm) 3.5 5 7 87 110 136 160 190 228 250 285 360 1/2'' 13mm 3.5 5 7 170 228 250 160 190 228 326 418 456 5/8'' 16mm 3.5 5 7 285 360 380 160 190 228 399 510 580
    read more
  • Dry Powder Fire Nozzle
    Fire Fighting Chemical Attack Dry Powder Fire Nozzle
    Fire Fighting Chemical Attack Dry Powder Fire Nozzle Winner Attack Dry Powder Nozzle is a highly effective, robust and lightweight nozzle designed, providing high performance delivery of a wide range of dry powder extinguishing agents.   Manufactured from hard anodised aluminium and fitted, the Attack Dry Powder Nozzle is designed to provide excellent corrosion resistance and is suited to multiple applications across a range of industry sectors and fire risk scenarios.   Principally used to combat fires in flammable liquids, gases, and greases (Class B) the Attack Dry Powder Nozzle fulfills multiple applications including the protection of refinery processes and industrial machinery.   Available in a choice on two standard threaded inlets (1” NH female or 1” BSP female) for compatibility to all international inlet fittings (available on request).   Features: Strong Light Weight Aluminum Construction. With Shut off Ball Valve Anodized and anticorrosive. T5 heat treatment. Working Pressure: 10Bar.  Connections Size Available: M39x2, Φ32 Max Flow Distance: 16M Suitable for oily fire such as oil depots, oil field, chemicals and etc   Key Users: Aviation Defence Industrial Petrochemical Machinery Plants Fire Training Centres
    read more
  • Automatic Fire Nozzle
    500 LPM Constant Flow Pistol Grip Automatic Fire Nozzle
    500 LPM Constant Flow Pistol Grip Automatic Fire Nozzle Winner turbo jet fire nozzle is a constant flow nozzle(flow remains constant and stable in all patterns). It can remain working when you change from different modes straight stream, fog spray or flush without shutting down. Main Features 1. Mainly equipped with firefighting forces and professional fire brigades for various fires. 2. Strong lightweight aluminum construction. 3. The flow rate is automatic adjusted based on the change of water pressure. 4. The water column has a long and stable range, and it still maintains quality range stability even at low pressure. 5. The recoil force is small. When it is pressurized or decompressed, the delay function works as a constant pressure to buffer the water flow change, which eliminate the recoil force on user and relieve the physical intensity on the user. 6. Nozzle is equipped with an atomized cone to make the spray more refined and better heat absorption effect. 7. Anodized and anticorrosive. T5 heat treatment.    Product Parameter    Weight (excl.coupling) 2.2 kgs Material Body Lightweight hard anodized aluminum Valve Aluminum Handle Horseshoe (Injection Molded Nylon red Handle) Bumper Rubber Working pressure 7 bar (100 psi) Max. pressure 25 bar (360 psi) Max. fog angle 130 ° Throw range 38 meter @ 7 bar Flow range 500 LPM (Automatic) Flush Inlet Size 1.5" (40 mm) Inlet coupling style Storz,INST.,NH,GOST,etc.
    read more
  • Forest Fire Nozzle
    1 Inch Compact Wildland Forest Fire Nozzle Gun
    1 Inch Compact Wildland Forest Fire Nozzle Gun Winner Forest Fire Nozzle is economical, lightweight, and dependable nozzles. Their rugged construction is compatible with the use of fresh water as well as firefighting foam concentrate. Other important operating features include: * Quick-acting pattern control from straight stream to wide fog * Fixed fog teeth; * Metal spinning fog teeth available on some models; * Easily flushable while flowing to clear trapped debris; * Quick-change fire hose coupling;   Forest Fire Nozzle has a selectable flow range at 7 bar of 15,30,45 and 60 litres per minute to meet the individual needs of the fire fighter at any given time but alternative flow rates are available.   Features:   Model WFN - F25 Flow rate 15 - 30 - 45 - 60 LPM - Flush (Selectable) Working  pressure 0.7MPa Inlet size 1"; 1.5"  Coupling srandard STORZ; GOST;INST; etc. Material Hard anodized aluminium alloy
    read more
  • Marine Fire Nozzle
    115 - 475 LPM Adjustable Flow Brass Marine Fire Nozzle
    115 - 475 LPM Adjustable Spray Gun Type Fire Nozzle Winner marine fire nozzle is a constant flow nozzle with multiple flow settings for operator flow control. The marine fire nozzle has four flow classes,115-230-360-475 LPS, and it is available both for straight stream,fog spray and flush without shutting down. Main Features 1) Pattern Identification. 2) Hard Anodized Aluminum labels,Laser Engraved. 3) Simple to operate (1/4 turn from straight stream to fog) 4) Raised lug marks straight stream for limited visibility operations  5) Easy to service and repair. 6) CCC certificate. 7) Compatible with Quick Attach Foam Tube   Product Parameter    Weight (excl.coupling) 1.6 kgs Material Body Lightweight hard anodized aluminum Valve ABS Handle ABS Bumper Rubber Working pressure 7 bar (100 psi) Max. pressure 25 bar (360 psi) Max. fog angle 120 ° Throw range 40 meter @ 7 bar Flow range (selectable) 115 LPS @7 bar 230 LPS @7 bar 360 LPS @7 bar 475 LPS @7 bar Flush Inlet size 1.5 inch, 2 inch, 2.5 inch (Optional). Connection coupling Storz,BS,NH,GOST,etc.
    read more
  • UL Listed Fire Sprinkler
    UL Listed Fire Sprinkler Head Pendent 5.6 K factor
    UL Listed Fire Sprinkler Head Pendent 5.6 K factor Introduction: Sprinklers are designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with compact design. available in different finishes and temperature ratings.   Style Pendent K Factor gpm/(psi)½( L³/min(bar)½ ) 5.6 (80) Nominal Thread Size 1/2” NPT AND 1/2” BSPT Max. Working Pressure 175 PSI (12BAR) Min. Operating Pressure 7 PSI (0.5 BAR) Factory Test Pressure 500 PSI (35BAR)   Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.  
    read more
  • Fire Sprinkler UL Listed
    DN15 Glass Bulb 5.6 K Factor Vertical Upright Fire Sprinkler UL Listed
    DN15 Glass Bulb 5.6 K Factor Vertical Upright Fire Sprinkler UL Listed Introduction: Sprinklers are designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with compact design. available in different finishes and temperature ratings.   Style Upright K Factor gpm/(psi)½( L³/min(bar)½ ) 5.6 (80) Nominal Thread Size 1/2” NPT AND 1/2” BSPT Max. Working Pressure 175 PSI (12BAR) Min. Operating Pressure 7 PSI (0.5 BAR) Factory Test Pressure 500 PSI (35BAR)   Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.  
    read more
  • UL Sidewall Fire Sprinkler
    UL Listed Glass Bulb Horizontal Sidewall Fire Sprinkler
    UL Listed Glass Bulb Horizontal Sidewall Fire Sprinkler Introduction: Fire sprinkler head is an important part of wet-type auto spraying system. It is usually installed inside the building and structures with light fire danger, medium fire danger and heavy fire danger, such as workshop, warehouse, hotel, shop, recreational place, hospital, cinema, office building and garage. Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.   Reaction Temperature of Different Types of Sprinklers:  
    read more
  • K115 Fire Sprinkler
  • Fire Sprinkler K115
  • ESFR Fire Sprinkler Head

top

Online Now