PVC Line Fire Hose
adjustable-flow-water-cannon

  • Vietnam Fire Hydrant
    Vietnam Fire Hydrant Water Distribution Valve
      Vietnam Fire Hydrant Water Distribution Valve Vietnam Fire Hydrant is used in warm areas with water in the barrel always. The outlets are individually controlled and the mechanical parts are easy to access above ground.   Specification Body material: Cast Iron  Outlet: DN65 Working pressure: 10bar (KG/CM2) Finishing: Red Epoxy coated Body     Ductile iron O-ring NBR Hose Outlet 2.5" Mounted Tooth and Lid  Aluminum Features: 1. Connect fire hose  with  water pipes quickly and conveniently. 2. Cast iron with high strength and durability. 3. An important equipment for urban roads, residential areas, industrial parks and some establishments where to guard public safety Just feel free to contact us or leave message for sample, price or details specifications, catalog or test report.
    read more
  • Fire sprinkler type,ZST fire sprinkler,CCC fire sprinkler,CE Fire sprinkler
  • Pistol Grip Fire Nozzle
    360 - 950LPM Adjustable Flow Handline Pistol Grip Fire Nozzle
    360 - 950LPM Adjustable Flow Handline Pistol Grip Fire Nozzle Winner WFSN-950 pistol grip fire nozzle is a constant gallonage nozzle(flow remains the same in all patterns), with multiple flow settings for operator flow control.The WFSN-950 has four flow classes,360-475-570-760-950 LPM, and it is available both for straight stream,fog spray and flush without shutting down. Main Features 1) Pattern Identification. 2) Anodized Aluminum labels,Laser Engraved. 3) Simple to operate (1/4 turn from straight stream to fog) 4) Raised lug marks straight stream for limited visibility operations  5) Easy to service and repair. 6) CCC certificate. 7) Compatible with Quick Attach Foam Tube   Product Parameter  Model Number QLD6.0/15III-C Weight 2.7 kg Operation Type Handline Spray Pattern  Jet and fog Spray Swivel Inlet 2.5" ( 65mm ) recommended Coupling Storz/NH/BSP/Russian type, etc. Length 260mm Flow Control Method 360-475-570-760-950 L/min Working Pressure  7 Bar Max Reach @ Max Flow 37 m Max fog angle 130 degree Nozzle Type Selectable Flow Nozzle Media Water Application Fire fighting, Industrial
    read more
  • Fire Water Nozzle
    400 - 2000LPM Fireman Holds and Adjust Fire Water Nozzle
    400 - 2000LPM Fireman Holds and Adjust Fire Water Nozzle Winner WFSN-2000 pistol grip fire nozzle is a constant gallonage nozzle(flow remains the same in all patterns), with multiple flow settings for operator flow control.The WFSN-950 has four flow classes,400-2000 LPS, and it is available both for straight stream,fog spray and flush without shutting down. Main Features 1) Pattern Identification. 2) Hard Anodized Aluminum labels,Laser Engraved. 3) Simple to operate (1/4 turn from straight stream to fog) 4) Raised lug marks straight stream for limited visibility operations  5) Easy to service and repair. 6) CCC certificate. 7) Compatible with Quick Attach Foam Tube   Product Parameter    Swivel Inlet 1.5" ( 40mm ) recommended Operation Type Pistol Grip Type Nozzle Type Automatic Nozzle,constant pressure, variable flow, constant gallonage, flow does not change with pattern Inlet Size 1.5 inch ,2 inch ,2.5 inch Coupling Storz/NH/BSP/Russian type, etc. Flow Rate 400-2000 L/min automatic Spray Pattern Jet and fog spray Media Water Application Fire fighting,fire hose,firefighter,fire hydrant Working Pressure 7 Bar Max Reach@Max Flow 60 Meters Max Fog Angle 120 degree
    read more
  • Fire Pump Connector
    Vietnam Throat to Receive Water Fire Pump Connector
    Vietnam Throat to Receive Water Fire Pump Connector It is used to supply water to the fire fighting system by pumping water directly into the throat. The equipment is attached to the fire-fighting water pipe.   Water-receiving plants or fire-fighting pillars are often installed in conjunction with a fire-fighting system. Used to pump water from fire engines for the system.   Specification Body material: Cast Iron  Outlet: DN65 Inlet: DN100 Working pressure: 10bar (KG/CM2) Finishing: Red Epoxy coated   2.Parameters Body       Ductile iron O-ring NBR Hose Outlet 2.5" Mounted Tooth and Lid  Aluminum Features: 1. Connect fire hose  with  water pipes quickly and conveniently. 2. Cast iron with high strength and durability. 3. An important equipment for urban roads, residential areas, industrial parks and some establishments where to guard public safety Just feel free to contact us or leave message for sample, price or details specifications, catalog or test report.
    read more
  • Thread Gate Valve
    Ductile Iron Water Seal Thread Gate Valve PN16
    Ductile Iron Water Seal Thread Gate Valve PN16 A gate valve, also known as a sluice valve, is a valve that opens by lifting a barrier (gate) out of the path of the fluid. Gate valves require very little space along the pipe axis and hardly restrict the flow of fluid when the gate is fully opened. The gate faces can be parallel but are most commonly wedge-shaped (in order to be able to apply pressure on the sealing surface).   Gate valves are used to shut off the flow of liquids rather than for flow regulation. When fully open, the typical gate valve has no obstruction in the flow path, resulting in very low flow resistance.   Gate Valve Applications Gate valves are used in almost all fluid services such as air, fuel gas, feedwater, steam, lube oil, hydrocarbon, and all most any services. Some special gate valve is used in slurry and powder product also such as knife gate valve Advantages of Gate Valve Gate valve provides good pressure drop during operation  Most of the gate valve can be used as bi-directional They are suitable for high pressure and temperature application and required less maintenance
    read more
  • Pressure Release Valve
    Water Pressure Release Valve for Fire Fighting
    Water Pressure Release Valve for Fire Fighting The valve consists of the main valve and outside installed control pilot valve, mainly installed in the bypass of the protected water supply system in the building, guarantee the pressure of the main valve upstream water supply zone, when the pressure in the water supply pipe exceeds the pressure set by the pressure releasing valve, the pressure releasing valve is switched on to prevent pipeline and equipment from damage by pressure exceeding. This valve is mainly used in pressure releasing of the fire test circulation system in high-rise buildings, is the upgrade replacement product of the spring safety valve.   Features: 1)Reasonable and novel structure, reasonable use of the hydraulic principle to control. 2)Long service life. 3)Valve clack quick opening and slow closure, no water hammer impacting. 4)High sensitivity, safe pressure discharge. 5)Stable operation, no noise.
    read more
  • Pressure Relief Valve
    Water Pressure Relief Valve for Fire Fighting
    Water Pressure Relief Valve for Fire Fighting This valve is used for the high building fore-fighting system,To prevent the pipeline and equipment damage due to overpressure. The body uses full passage streamline design, of a small fluid resistance and a heavy flow. This valve can be used as either a pressure releasing or holding valve.  when used as the former, it can release the pressure surpassing the safe value set with the pilot valve and keep the pressure inside of the pipeline below the safe value to prevent system against danger due to an excessively high water pressure;while used as the latter,it can keep the upstream water supply pressure of the main valve over some set value,this is because water supply to the downstream can not be done,unless the upstream is higher than the set value,in order to make sure of he upstream water supply pressure of the main valve.
    read more
  • Water Gate Valve
    Ductile Iron Groove Type Signal 6 Inch Water Gate Valve
    Ductile Iron Groove Type Signal 6 Inch Water Gate Valve The signal gate valve is mainly used in the pipeline of the fire water system as a function of opening and intercepting the fluid in the pipeline, and converting the opening and closing working state into an electric signal through the signal device. The elastic seat sealing gate valve signal gate valve encapsulating the whole valve disc to generate a deformation compensation effect to achieve a good sealing effect, overcome the general gate valve sealing failure, water leakage, and rust phenomenon, more effective saving installation space.   It's mainly composed by the signal device, valve body, valve cover, disc assembly, stem, stem nut, hand wheel and other components. The annunciator is mainly composed of a transmission gear, a transmission rod and a micro switch. Gate Valve Applications Gate valves are used in almost all fluid services such as air, fuel gas, feedwater, steam, lube oil, hydrocarbon, and all most any services. Some special gate valve is used in slurry and powder product also such as knife gate valve Advantages of Gate Valve Gate valve provides good pressure drop during operation  Most of the gate valve can be used as bi-directional They are suitable for high pressure and temperature application and required less maintenance
    read more
  • High Velocity Water Spray Nozzle
  • Medium Velocity Spray Nozzles
  • Fire sprinkler type,ZST fire sprinkler,CCC fire sprinkler,CE Fire sprinkler
  • Fire Monitor
    Aluminum Alloy Fixed Manual Fire Water Monitor
    Aluminum Alloy Fixed Manual Fire Water Monitor   1.Product Introduction  Manual Fire Monitor has characteristics with adjustable flow rate, distant range, and wide discharging range and the discharge range is also adjustable-----have both straight stream and fog stream. Manual fire monitors can be installed in places of flammable or explosive chemical circumstances, airports, oil areas, oil transport wharves, shipyards, etc.   It is an efficient equipment for putting out fire, and it is can also be fixed on fire vehicles.    2.Product Parameter  Model PS20 PS30 PS40 PS50 PS60 Flow Rate (Liter/Second) 20 30 40 50 60 Working Pressure(Mpa) 0.8 0.8 0.8 0.8 0.9 Max Working Pressure(Mpa) 1.0 1.0 1.0 1.0 1.2 Flange Connection(mm) DN80 DN80 DN80 DN80 DN100 Water Jetting Range(m) ≥50 ≥60 ≥65 ≥70 ≥75 Horizontal Angle (Degree) 0-360 0-360 0-360 0-360 0-360 Max Angle Of Elevation (Degree) 85 85 85 85 85 Max Angle Of Depression (Degree) -60 -60 -60 -60 -60
    read more
  • Fire Water Cannon
    Fixed Manual Fire Water Cannon
    Fixed Manual Fire Water Cannon This fire water cannon is the latest self-designed technology at home and abroad. The key parts have been improved. It is simple, novel, stable and reliable, flexible in operation and convenient in maintenance. When spraying water column, it can extinguish solid fire; when spraying water mist, it can be used for cooling of fire field, fire rescue, and can also be used for cooling of storage tanks such as oil storage tank area, benzene tank area and methanol tank area. It can effectively absorb the heat in the air at the fire site and absorb the toxic and harmful gases such as smoke and chlorine in the diluted air, which improves the safety factor of firefighters. Applicable to areas of offshore oil rigs, ports, dock oil depots, marine firefighting vessels and other fire extinguishing media. Products Features 1, simple operation, flexible, long range 2, with flow adjustment function 3, horizontal rotation, pitch rotation 4, with straight stream and spary function Product Parameter Model Flow(L/s) Range(m) Working Pressure(MPa) Max Elevation Angle(°) Max Depression Angel(°) Horizontal Rotation Ange(°) Flange PS30 30 ≥55 0.8-1.0 60 -40 0-360 Dn80 PS40 40 ≥60 PS50 50 ≥65
    read more
  • Fire Department Connection
    Forged Y Siamese Water Divider Straight Fire Department Connection
    Forged Y Siamese Water Divider Straight Fire Department Connection Fire department connection is one of the most important and convenient allies for firefighters on-site. Because of this, there are several requirements in place to guarantee its accessibility. One of them has to do with the distance between a building’s fire hydrant and its Siamese connection. The two Siamese couplings connect servicing hoses that pump water from fire engines. • Single clapper / double clapper designs • Technical: Forged • 2 1/2” swivels ring are pin lug design for ease of use and compatibility with local fire service districts. • Including 2 plug of U.S.A. 2.5" NST polished with chain and plate for fire department.   Code No. Inlet size Outlet size WF - FDC01 F 4”BSP 2xF2.5”NST WF - FDC01A F 4”NPT 2xF2.5”NST
    read more
  • 90 Brass Water Divider
    FDC 90 Brass Water Divider Fire Department Connection
    FDC 90 Brass Water Divider Fire Department Connection  Fire department connection is one of the most important and convenient allies for firefighters on-site. Because of this, there are several requirements in place to guarantee its accessibility. One of them has to do with the distance between a building’s fire hydrant and its Siamese connection. The two Siamese couplings connect servicing hoses that pump water from fire engines. • Single clapper / double clapper designs • Technical: Forged • 2 1/2” swivels ring are pin lug design for ease of use and compatibility with local fire service districts. • Including 2 plug of U.S.A. 2.5" NST polished with chain and plate for fire department.   Code No. Inlet size Outlet size WF - FDC02 F 4”BSP 2xF2.5”NST WF - FDC02A F 4”NPT 2xF2.5”NST

    Related Tags :

    FDC 90 Brass Water Divider
    read more

top

Online Now