PVC Line Fire Hose
Products

UL Fire Sprinkler

  • UL Listed Fire Sprinkler
    UL Listed Fire Sprinkler Head Pendent 5.6 K factor
    UL Listed Fire Sprinkler Head Pendent 5.6 K factor Introduction: Sprinklers are designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with compact design. available in different finishes and temperature ratings.   Style Pendent K Factor gpm/(psi)½( L³/min(bar)½ ) 5.6 (80) Nominal Thread Size 1/2” NPT AND 1/2” BSPT Max. Working Pressure 175 PSI (12BAR) Min. Operating Pressure 7 PSI (0.5 BAR) Factory Test Pressure 500 PSI (35BAR)   Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.  
    inquiry now read more
  • Fire Sprinkler UL Listed
    DN15 Glass Bulb 5.6 K Factor Vertical Upright Fire Sprinkler UL Listed
    DN15 Glass Bulb 5.6 K Factor Vertical Upright Fire Sprinkler UL Listed Introduction: Sprinklers are designed for use in automatic sprinkler systems designed in accordance with standard installation (NFPA13). The temperature response is standard response 5mm glass bulb and fast response 3mm glass bulb. The sprinklers come with compact design. available in different finishes and temperature ratings.   Style Upright K Factor gpm/(psi)½( L³/min(bar)½ ) 5.6 (80) Nominal Thread Size 1/2” NPT AND 1/2” BSPT Max. Working Pressure 175 PSI (12BAR) Min. Operating Pressure 7 PSI (0.5 BAR) Factory Test Pressure 500 PSI (35BAR)   Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.  
    inquiry now read more
  • UL Sidewall Fire Sprinkler
    UL Listed Glass Bulb Horizontal Sidewall Fire Sprinkler
    UL Listed Glass Bulb Horizontal Sidewall Fire Sprinkler Introduction: Fire sprinkler head is an important part of wet-type auto spraying system. It is usually installed inside the building and structures with light fire danger, medium fire danger and heavy fire danger, such as workshop, warehouse, hotel, shop, recreational place, hospital, cinema, office building and garage. Installation,Usage and Maintenance: During installation, should pay attention not to damage the bulb to avoid affect the thermal performance. In the process of wrench and twist, do not use spanner to wrench the supporting arm to deformation and affect thesealing performance (note: the bulb temperature can be chosen according to the needs of users)   Product Feature: It can not only detect the fire, but also extinguish the fire by spraying water.   Application: It is usually installed in areas with fire danger, including warehouses, shopping malls, hotels, hospitals, theaters, office building, high-rise building, garages and etc.   Reaction Temperature of Different Types of Sprinklers:  
    inquiry now read more
  • UL Fire Sprinkler
  • UL/FM fire sprinkler

top

Online Now